Kasco's C-25 GFCI Control Box is a standard component included in the 1400JF, 2400VFX, 3400VFX, 3400JF, and 4400VFX Floating Aerating Fountain packages and is optional with any 120V Pond Aerator or Water Circulator. The C-25 is a plug-and-go model control box that is customer installable for quick and easy set-up, no hard wiring is necessary.
C-25 features
NOTE: No one should ever enter the water with electrical equipment in operation or even plugged into the control panel or outlet. It is essential that the GFI breaker is tested once a month to ensure proper operation. Check instructions for procedure.
C-25 TIMER CONTROL INSTRUCTIONS
Portable Timer with Ground Fault Interrupter
(UNIT: 9.8 FLA, 58.8 LRA 120 VAC
LIGHT: 300 W, 120 VAC)
IMPORTANT
This portable timer is designed for CONTROLLING the connected equipment only. Unplug timer before
servicing the unit or the equipment it controls. THIS SWITCH IS NOT TO BE USED AS A POWER
DISCONNECT! For maximum protection against electrical shock hazard, perform test procedure on
G.F.C.I. at least once a month. Mount at least 5 ft. from open water.
G.F.C.I. TEST PROCEDURE
The G.F.C.I. should be checked every month to make sure that it is operating properly. Just follow the
simple instruction below. It is recommended to maintain a maintenance diary of your monthly safety
check.
1. Push TEST button, RESET button should pop out from inner surface. This should result
in power being OFF at the outlet protected by the G.F.C.I. Verify by plugging test lamp
into the outlet. Be sure the timer is in the ON position.
2. If the G.F.C.I. tests okay, restore power by pushing the RESET button back in. THE
RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL
IT LOCKS AND REMAINS DEPRESSED AFTER PRESSURE HAS BEEN
REMOVED.
DANGER: IF RESET BUTTON DOES NOT POP OUT, IF TEST LAMP REMAINS
LIT WHEN RESET BUTTON DOES POP OUT, OR IF THE G.F.C.I. FAILS TO
RESET PROPERLY, DO NOT USE TIMER! CONTACT US.
Failure to use the C-25 with Kasco fountains will void the warranty and cause the fountain to not be listed
to UL and CSA standards via ETL.
UNDER NO CIRCUMSTANCES SHOULD ANYONE ENTER THE WATER
WHEN A UNIT IS IN OPERATION.
TIMER-OPERATING INSTRUCTIONS
C-25 Control box will turn the aerator/fountain ON & OFF with the Timer. Kasco lights will turn ON
with the Photo Eye and OFF with Timer. C-25 Control box is to be used with Kasco Approved Lights
ONLY!
1. Insert “ON” (GREEN) and “OFF” (RED) trippers into dial at desired ON and OFF
times.
2. Turn dial clockwise one or more revolutions until correct time-of-day (AM or PM) in
window is aligned with arrow.
3. Plug aerator/fountain cord into the RIGHT hand outlet (labeled PUMP).
4. Plug transformer cord into LEFT hand outlet (labeled LIGHT).
5. Set Transformer Timer dial to be ON 24 hours per day. (Lights will then run on the
Photo Eye on C-25.)
FOR TEMPORARY MANUAL OPERATION
Rotate MANUAL knob counter-clockwise (